Introduction
What is NetSim?
The manual
Basic principles
Basic elements
Nodes
Pipes
Boundary conditions
Dimensioning
Dynamic calculations
Steam module
Year simulation
District cooling
What should I do?
Start NetSim
Pipe types
Create a new pipe type
Create a new model
Create pipes
Create the first pipe
Create the second and subsequent pipes
Divide an existing pipe
Delete an object
Calculatable network
Create production plant
Create consumption in the model
Enter calculation conditions
Execute calculation
Identify holes in model (additional function)
Calculate
Troubleshoot model
Fault-free model
Sectioning option (additional function)
Divide model (additional function)
Supplement the model with consumption/customers
Create a customer via a customer data form.
Import customer from external file
Several production plants
Production plants
Position a heat exchanger
Pressure regulations
Define a pressure increase station
Define a pressure reduction
Analyse calculation results
Summary calculation results
Map plots
Graphs
Table data
NetSim system summary Vitec Release Manager
Modelling
Results anaysis
User interface
General information on forms
Graphic window
File menu
Connect database
Update current model
Model
Create new...
Copy...
Delete...
Calculation...
Import DWG (additional function)
Import calculation file...
Customer data
Import new only...
Import all...
Copy customers...
Delete customers...
Export customer data
Load background...
Delete background...
Save drawing as...
Print..
Exit NetSim
Display menu
Background colour
Layer properties management
Text (additional function)
Zoom window
Zoom boundaries
Zoom node
Zoom pipe
Zoom previous
Pan
Filter in grid
Show selections on the map
Show level division
Tools menu
Notification
Execute level division
Reduce number of pipes
Settings
Modules menu
Reports menu
Help menu
Toolboxes
Database
Modules
Tools
Own toolbox
Model data form
Node form
Pipe form
Production plant form
Pump form
Valve form
Heat exchanger form
Accumulator form
Customer form
Annual data form
System data form
Pump type
Valve type
Customer type
Temperature curves
Node type/time series
Status list
Calculation
File types
Results analysis
Map
Charts
Node table
Pipe table
Out
Animation
Model management
General
Model concepts
Model-specific data
Objects
Directory data
Copy a model
Delete a model
Pressure regulations - pumps and valves
Location of pumps and valves
Example
Import from CAD
Data import from CAD file (additional function)
Drawing style
Interpretation
Naming methods and prefixes
INTERPRETATION
Create a calculatable model
Combine interpreted model with existing model
Editing a drawing in the interpretation module
Data import from network information system
Consumption data
Import file for customer data
Import file preparation
Import customer data to NetSim databas
Update nodes with consumption from customer data
Customer data field description
Input data in general
Summing of customer data to node
Factor-controlled power
Factor-controlled cooling
Calculation module's input data file
Summary
Data format
Summary: keywords
Keywords
Keyword *ACCU
Keyword *ATMP
Keyword *COOL
Keyword *DIAM
Keyword *FFAC
Keyword *FORW
Keyword *HEAT
Keyword *ILIM
Keyword *VERS
Keyword *LDIM
Keyword *NODE
Keyword *PFAC
Keyword *PIPE
Keyword *PSUP
Keyword *PUMP
Keyword *PQTA
Keyword *SHNT
Keyword *STEA
Keyword *STOP
Keyword *TEMP
Keyword *TITL
Keyword *VALV
Keyword *DYNP
Keyword *YEAR
Time series
Keyword *QFAC
Keyword *EFAC
Keyword *TINL
Keyword *OFAC
Keyword *OUTP
Error messages
Mathematical and physical basics
Calculation procedure
Input data
Pressure
Temperature
Valves and pumps
Bypasses
Density and viscosity
Shunt valve
Accumulators
Examples of pipe types
Glossary of Terms