A type for power, return temperature and cooling as a function of outdoor temperature must be related to all customers.

The grid form shows the type name and the ID of the type in the database. N.B The type ID must be specified in the import file for customers! If the import file contains types which do not exist in the database, these types are created in the database with a linear function which you can adapt to the required appearance after import. Up to 99 different type curves can be specified in the database.

In ascending order with regard to outdoor temperature, enter the factor by which the customer's power, return temperature and cooling is to be multiplied in order to adapt the value to a given outdoor temperature (load case).  The calculation form specifies an outdoor temperature for the load case, and use the curves above to sum customers' power/cooling/return temperature to the nodes.