When updating nodes with consumption from customer data, all customers' loads are summed to the node to which the customer is related. The resulting cooling or return temperature written to the node is a weighted average value for all customers connected to the node. The update affects the active model only.
1. Start NetSim, connect to the database and select the model.
2. Select in the menu Arkiv [File → Beräkning [Calculation.
3. In the kundfaktorer [customer factors section, enter a value for outdoor temperature.
4. Indicate the customer data field from which som the customer's power is to be calculated.
5. Indicate the network level to which summing is to take place.
6. Select whether cooling or return temperature is to be transferred to the nodes.
8. Press the Uppdatera knutar [Update nodes button, or press the Bypass button if
bypasses at customers' premises are to be summed to the nodes.
9. Close the form.