Keyword *TINL

This keyword is used to control supply pipe temperature from production plants for every node type. This keyword is given for every occurring node type in the calculation. Up to 14 values can be given for time and temperature. This keyword is ended with /. Time is specified with decimals used to indicate part-hours. In the calculation, given temperatures are interpolated between given times.

FORMAT:

*TINL Typ:Nodetyp

Tidpunkt1 Temperatur

Tidpunkt2 Temperatur

...

Tidpunkti  Temperatur

/

Where:

Nodetyp                  Node type 1 to 10

Tidpunkt        Time (decimal).

Temperatur    Supply pipe temperature.

Example:

* TINL Typ: 1

 

         0.00       100.0

         1.00       100.0

         5.50       110.0

         7.00       115.0

         8.00       110.0

         9.00       110.0

     12.00     100.0

     14.00     100.0

     15.00     100.0

     16.00     100.0

     17.00     100.0

     18.00     100.0

     19.00     100.0

     23.00     100.0

 /