Keyword *VALV

This keyword is used to enter data for pressure-regulating valves.

FORMAT:

*VALV  <ledningsid, sida, alfa, alfa1, kv1, alfa2, kv2,....., alfa10, kv10> /

Where:

ledningsid      :        Pipe identification  (-)               

sida       :     0 both supply and return           

                             1 supply

                             2 return

alfa        :     Valve opening degree (degrees) (0 = closed valve)     

alfa1      :     Valve position (degrees)                        

kv1        :     Valve coefficient ((t/h)/bar½) (belongs to alfa1)

                   .

                   .

alfa10    :     Valve position (degrees)

kv10      :     Valve coefficient (belongs to alfa10)

Up to 10 data pairs of valve positions and valve coefficients can be entered. The table must be specified with decreasing valve position values.

If fewer than 10 data pairs are specified, the table must be ended with a “/” (slash).

Example:

*VALV

Pipe ID  : “R1”

Supply pipe : 1          

Valve characteristic:            

              Alfa                         Kv        

               90                          360

               75                          320            

               60                          280  

               45                          240   

               30                          200

               15                          160 /