The program calculates the current density and viscosity, corrected for pressure and temperature as per the following expression:
Where:
P = Absolute pressure [N/m2
P0 = Reference pressure = 0.1013 x 106 [N/m2
K = Bulk module = 2.1 x 109 [N/m2
T = Current temperature [K
T0 = Reference temperature 323.0 [ K
ρ0 = Reference density = 988 [kg/m3
Ґ0 = Reference viscosity = 0.00055 [kg/s/m)
α = Constant = -0.0139 [K-1
β = Constant = -5.47 x 10-4
Keyword *COOL introduces constants to the program which are suitable for the temperature range < 20 °C.