Storage of historical data

Note that this paragraph only applies to files with the suffix .aio, not to .el files. The resolution is controlled by the setting for resolution in the Extra2 field for the import protocol.

-       This applies for the Resolution setting.

-       Controls the time resolution in the AIO file if not already present. 

-       Valid values for resolution are 5, 10, 15, 20, 30 and 60.

-       If the file is already present, data is inserted with the resolution in the file, and this parameter is ignored.

-       If no file is present, it is created with this resolution and data is converted to it.

-       If this parameter is missing and the file is not present, the resolution will be the same as in the import file.

E.g.        Resolution:15     (Find out more in the manual for Import AFS)