Configured in file “MultipleModelDefinition.txt” (tab separated file that configure multiple models and connect them to load series)
Note
•NO headers in the file.
•Important that it contain the right number of columns (10) even if one column is empty!
•All columns must have a valid value and cannot left empty.
Names of columns and some example of raw in the text file to create and connect multiple models to series for a specific model position:
SeriesName To Connect To, ModelName, Model Position, DayTypeCalendar, SummerFile, HoursBeforUTC, ModelType, HoldOff, IgnoreGlob, IgnoreWind
-------------------------------------------------------------------------------------------------
PROFIL_ABB PROFIL_ABB_Mod2 2 finland_s.dt0 SOMMAR_FIN.DAT 2 Cilia 0 False False
PROFIL_ABB PROFIL_ABC_Mod3 3 finland_s.dt0 SOMMAR_FIN.DAT 2 Cilia 0 False False
PROFIL_ABB PROFIL_ABB_Mod4 4 finland_s.dt0 SOMMAR_FIN.DAT 2 Cilia 0 False False
PROFIL_ABB PROFIL_ABB_Mod5 5 finland_s.dt0 SOMMAR_FIN.DAT 2 Cilia 0 False False
PROFIL_ABC PROFIL_ABC_Mod2 2 finland_s.dt0 SOMMAR_FIN.DAT 2 Cilia 0 False False
PROFIL_ABC PROFIL_ABC_Mod3 3 finland_s.dt0 SOMMAR_FIN.DAT 2 Cilia 0 False False
PROFIL_ABC PROFIL_ABC_Mod4 4 finland_s.dt0 SOMMAR_FIN.DAT 2 Cilia 0 False False
PROFIL_ABC PROFIL_ABC_Mod5 5 finland_s.dt0 SOMMAR_FIN.DAT 2 Cilia 0 False False
-------------------------------------------------------------------------------------------------